Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.nuph.edu.ua/handle/123456789/23486
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorBlazheyevskiy, M. Ye.-
dc.contributor.authorMoroz, V.-
dc.contributor.authorБлажеєвський, М. Є.-
dc.contributor.authorБлажеевский, Н. Е.-
dc.date.accessioned2020-08-06T13:28:44Z-
dc.date.available2020-08-06T13:28:44Z-
dc.date.issued2020-
dc.identifier.citationBlazheyevskiy, M. Ye. Iodometric determination of cystamine dihydrochloride in tablets using diperoxyadipic acid / M. Ye. Blazheyevskiy, V. Moroz // French-Ukrainian Journal Of Chemistry. - 2020. - № 8(1). Р. 19-27. doi: http://dx.doi.org/10.17721/fujcV8I1P19-27uk_UA
dc.identifier.urihttp://dspace.nuph.edu.ua/handle/123456789/23486-
dc.descriptionBlazheyevskiy, M., & Moroz, V. (2020). Iodometric determination of cystamine dihydrochloride in tablets using diperoxyadipic acid. French-Ukrainian Journal Of Chemistry, 8(1), 19-27. doi:http://dx.doi.org/10.17721/fujcV8I1P19-27uk_UA
dc.description.abstractThe kinetics of cystamine dihydrochloride oxidation by diperoxyadipic acid (DPAA) was studied in aqueous buffer solutions of pH 2.9, 6.9, 8.0, 8.5 and 9.2 under second-order conditions at the temperature 293 K. The second order rate constants, k (L mol−1 min−1) were calculated from kinetic values. A suitable mechanism scheme based on these observations was proposed. The possibility of application of DPAA as reagent for oxidimetric determination of cystamine dihydrochloride in tabtets was investigated. Cystamine dihydrochloride was determined by indirect titration with DPAA. The required amount of Cystamine dihydrochloride was dissolved in water, pH 8.0 buffer solution and DPAA solution was added. After 7 min, the solution was acidified. The excess DPAA was determined via iodometric titration. The advantages of the applied analytical techniques in the determination of cystamine dihydrochloride in tablets «Cystamine 0.2 g» was presented. The recovery of сystamine dihydrochloride was 99.32±1.45%. A paired t-test showed that all results obtained for bulk drug and in tablets «Cystamine 0.2 g», using the proposed procedure and the official procedure respectively, agreed at the 95% confidence level.uk_UA
dc.language.isoenuk_UA
dc.subjectcystamineuk_UA
dc.subjectoxidationuk_UA
dc.subjectdiperoxyadipic aciduk_UA
dc.subjectKineticsuk_UA
dc.titleIodometric determination of cystamine dihydrochloride in tablets using diperoxyadipic aciduk_UA
dc.typeArticleuk_UA
Располагается в коллекциях:Наукові публікації кафедри загальної хімії

Файлы этого ресурса:
Файл Описание РазмерФормат 
Iodometric determination of cystamine dihydrochloride in tablets using.pdf812,9 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.