Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.nuph.edu.ua/handle/123456789/23542
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorMaslii, Yu. S.-
dc.contributor.authorRuban, O. A.-
dc.contributor.authorKasparaviciene, G.-
dc.contributor.authorKalveniene, Z.-
dc.contributor.authorMateriienko, A.-
dc.contributor.authorIvanauskas, L.-
dc.contributor.authorMazurkeviciute, A.-
dc.contributor.authorKopustinskiene, D. M.-
dc.contributor.authorBernatoniene, J.-
dc.date.accessioned2020-11-02T13:34:19Z-
dc.date.available2020-11-02T13:34:19Z-
dc.date.issued2020-
dc.identifier.citationThe Influence of pH Values on the Rheological, Textural and Release Properties of Carbomer Polacril® 40P-Based Dental Gel Formulation with Plant-Derived and Synthetic Active Components / Yu. S. Maslii, O. A. Ruban, G. Kasparaviciene, Z. Kalveniene, A. Materiienko, L. Ivanauskas, A. Marurkeviciute, Dalia M. Kopustinskiene, J. Bernatoniene // Molecules. - 2020. - Vol. 25, Issue 21. - Р. 5018.uk_UA
dc.identifier.urihttp://dspace.nuph.edu.ua/handle/123456789/23542-
dc.description.abstractThe physicochemical properties, especially pH value of dental medicines, have significant influence on the health of oral cavity tissues. The pH of formulations should correspond to the value of saliva pH (5.5–8.0). For carbomer-based gels, the required pH value is obtained by neutralizing them with alkaline components, which leads to their structuring (thickening). This affects the physical properties of the gel, its residence time at the application site and the rate of release of active pharmaceutical ingredient. Therefore, the main purpose of this study is to evaluate the rheological, textural, and biopharmaceutical properties of Carbomer Polacril® 40P-based dental gel depending on the pH value. Evaluation of the rheological properties of gel preparations were performed by measuring the structural viscosity of the samples as a function of pH and temperature. The textural properties of the gel were evaluated by performing tests regarding back extrusion and spreadability. Carbomer Polacril® 40P-based gels haven’t shown noticeable thixotropic behavior, and were characterized by plastic flow in the whole studied pH range. The structural viscosity at the selected average pH value hasn’t differed at storage (25 ◦C) and application (37 ◦C) temperature. Texture studies of dental gels have shown a strong correlation with rheoparameters. Their rheological behavior and textural properties haven’t changed significantly between the pH range of 5.5–6.6. The relatively narrow range of working pH values does not affect the change in the viscosity of the preparation significantly and, consequently, does not affect the release of APIs from the developed Carbomer Polacril® 40P-based dental gel.uk_UA
dc.language.isoenuk_UA
dc.subjectperiodontal tissueuk_UA
dc.subjectoral mucosa diseasesuk_UA
dc.subjectCarbomer Polacril® 40P-based geluk_UA
dc.subjectpHuk_UA
dc.subjectrheological studiesuk_UA
dc.subjecttextural analysisuk_UA
dc.subjectrelease testuk_UA
dc.titleThe Influence of pH Values on the Rheological, Textural and Release Properties of Carbomer Polacril® 40P-Based Dental Gel Formulation with Plant-Derived and Synthetic Active Componentsuk_UA
dc.typeArticleuk_UA
Располагается в коллекциях:Наукові публікації кафедри промислової технологiї лiкiв та косметичних засобів
Наукові публікації кафедри фармацевтичних технологій, стандартизації та сертифікації ліків ІПКСФ

Файлы этого ресурса:
Файл Описание РазмерФормат 
Molecules. 2020. Vol. 25(21).pdfThe Influence of pH Values on the Rheological, Textural and Release Properties of Carbomer Polacril® 40P-Based Dental Gel Formulation with Plant-Derived and Synthetic Active Components14,3 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.