Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://dspace.nuph.edu.ua/handle/123456789/26502
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Avruniri, O. G. | - |
dc.contributor.author | Bondarenko, I. S. | - |
dc.contributor.author | Gryshkov, O. P. | - |
dc.contributor.author | Glasmacher, B. | - |
dc.contributor.author | Bondarenko, S. I. | - |
dc.contributor.author | Krevsun, O. V. | - |
dc.contributor.author | Rakhimova, M. V. | - |
dc.contributor.author | Аврунін, О. Г. | - |
dc.contributor.author | Аврунин, О. Г. | - |
dc.contributor.author | Бондаренко, І. С. | - |
dc.contributor.author | Бондаренко, И. С. | - |
dc.contributor.author | Гришков, О. П. | - |
dc.contributor.author | Гришков, О. П. | - |
dc.contributor.author | Рахімова, М. В. | - |
dc.contributor.author | Рахимова, М. В. | - |
dc.contributor.author | Кревсун, О. В. | - |
dc.contributor.author | Кревсун, О. В. | - |
dc.contributor.author | Бондаренко, С. І. | - |
dc.contributor.author | Бондаренко, С. И. | - |
dc.date.accessioned | 2021-11-25T13:31:11Z | - |
dc.date.available | 2021-11-25T13:31:11Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Acoustomagnetic detection of magnetic nanoparticles in a model sample of biological substance / О. Avruniri, I. Bondarenko, O. Gryshkov, B. Glasmacher, S. Bondarenko, O, Krevsun, M. Rakhimova // The International Journal of Artificial Organs. – 2019. – Vol. 43. – Р. 429. | uk_UA |
dc.identifier.uri | http://dspace.nuph.edu.ua/handle/123456789/26502 | - |
dc.description | As measurements have shown, the magnitude of the voltage is proportional to the concentration of MNPs in the field of action of the ultrasound and the magnet field, as well as the intensity of the ultrasound. In particular, when the intensity of ultrasound was at the level of 0.02 W/ cm2, U = ImV was obtained | uk_UA |
dc.description.abstract | The experimental results are consistent with the calculated estimates and suggest that AMM can be used to detect MNPs in a real BS. Considering that the magnitude of the constant magnetic field in these experiments was 0.1T, we can also conclude that this method is safe, more accurate, and easier to implement than traditional X-ray and MRT methocjs. | uk_UA |
dc.language.iso | en | uk_UA |
dc.title | Acoustomagnetic detection of magnetic nanoparticles in a model sample of biological substance | uk_UA |
dc.type | Article | uk_UA |
Располагается в коллекциях: | Наукові публікації кафедри фармацевтичної хімії |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
Germany.pdf | 2,11 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.