Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.nuph.edu.ua/handle/123456789/28402
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorZuikina, Ye.V.-
dc.contributor.authorPolovko, N. P.-
dc.contributor.authorBevz, O. V.-
dc.contributor.authorBevz, N. Yu.-
dc.contributor.authorЗуйкіна, Є. В.-
dc.contributor.authorПоловко, Н. П.-
dc.contributor.authorБевз, О. В.-
dc.contributor.authorБевз, Н. Ю.-
dc.date.accessioned2022-09-28T08:53:07Z-
dc.date.available2022-09-28T08:53:07Z-
dc.date.issued2020-
dc.identifier.citationDevelopment of methods of boric acid quantitative determination in experimental ointment / Ye.V. Zuikina, N. P. Polovko, O. V. Bevz, N. Yu. Bevz // Modern pharmacy – science and practice proceedings : the in international scientific-practical internet conference, Kutaisi, 01.12.2020-21.12.2020. – Kutaisi : Georgia, 2020. – P. 87-91.uk_UA
dc.identifier.urihttp://dspace.nuph.edu.ua/handle/123456789/28402-
dc.description.abstractA method for the quantitative determination of boric acid by alkalimetric method in mild experimental dosage forms is proposed. The aqueous boric acid solution was titrated with 0.1 M sodium hydroxide solution in the presence of mannitol to establish the end point of the titration by an indicator method using phenolphthalein solution. When studying the validation characteristics, we calculated the complete uncertainty of the analytical methodology, determined the parameters of linearity, accuracy and precision. According to the results of the study, it was found that the alkalimetric method is linear in concentrations from 80% to 120% of the selected concentration according to the method (correlation coefficient 0.9993 ≥ 0.9981). The method is precise because the value of the relative confidence interval Δ.% 1.19 ≤ 1.60% is found and is correct, as the criterion of uncertainty of systematic error 0.31% is fulfilled. The developed method of quantitative determination of boric acid by alkalimetric method can be used to analyze the experimental soft dosage form and study the stability of the dosage form. The obtained results are metrologically certified.uk_UA
dc.language.isoenuk_UA
dc.subjectboric aciduk_UA
dc.subjectquantitative determinationuk_UA
dc.subjectalkalimetryuk_UA
dc.subjectmild dosage formuk_UA
dc.subjectкислота борнаuk_UA
dc.subjectкількісне визначенняuk_UA
dc.subjectалкаліметріяuk_UA
dc.subjectм'яка лікарська формаuk_UA
dc.titleDevelopment of methods of boric acid quantitative determination in experimental ointmentuk_UA
dc.title.alternativeРозробка методів кількісного визначення борної кислоти в експериментальній мазіuk_UA
dc.typeArticleuk_UA
Располагается в коллекциях:Наукові публікації кафедри медичної хiмiї

Файлы этого ресурса:
Файл Описание РазмерФормат 
KUTAISI 2020 CONFERENCE_PROCEEDINGS Бевз.pdf645,82 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.