Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.nuph.edu.ua/handle/123456789/34241
Название: Determination of chromatographic conditions for quantitative assessment of active components in complex nasal spray after manufacturing and expiry date
Авторы: Cherniakova, Valeriia
Myhal, Artem
Rudiuk, Vitalii
Kryvanych, Оleksandr
Tugaibei, Igor
Rudakova, Olha
Bevz, Nataliia
Georgiyants, Victoriya
Чернякова, Валерія
Мигаль, Артем
Рудюк, Віталій
Криванич, Олександр
Тугайбей, Ігор
Рудакова, Ольга
Бевз, Наталія
Георгіянц, Вікторія
Ключевые слова: spray;phenylephrine hydrochloride;lidocaine hydrochloride;polyvinylpyrrolidone;panthenol;nitrofural;diphenhydramine hydrochloride;quantitative determination;liquid chromatography;stability
Дата публикации: 3-окт-2024
Библиографическое описание: Determination of chromatographic conditions for quantitative assessment of active components in complex nasal spray after manufacturing and expiry date / V. Cherniakova [et al.] // ScienceRise: Pharmaceutical Science. - 2024. - № 1(47). - Р. 30–39. https://doi.org/10.15587/2519-4852.2024.299184 Scopus, Q3
Краткий осмотр (реферат): The aim of the work is the development of chromatographic conditions, the study of the validation characteristics of the method of quantitative determination of phenylephrine hydrochloride, nitrofural, lidocaine hydrochloride and diphenhydramine hydrochloride, panthenol, povidone in the joint presence in the nasal spray by a complex method of liquid chromatography with UV detection. Evaluation of the quantitative content of active components after manufacturing and during the shelf life. Materials and methods. Agilent 1260 liquid chromatographs, equipped with a diode-matrix detector from the company “Agilent technologies”, USA. Chromatographic columns 250×4.6 mm in size, filled with octadecylsilyl silica gel for chromatography (Zorbax StableBond SB-Aq, Agilent company), mobile phase A – phosphate buffer solution pH 7.0 – acetonitrile P (1650:350), mobile phase B – acetonitrile P; elution mode – gradient; mobile phase flow rate – 1.0 ml/min; detection wavelengths – 220 nm (for panthenol, phenylephrine, povidone, diphenhydramine) and 235 nm (for nitrofural and lidocaine). Results. Chromatographic separation conditions were developed for the co-presence determination of six target substances: panthenol, phenylephrine hydrochloride, nitrofural, povidone, lidocaine hydrochloride and diphenhydramine hydrochloride. The suitability of the technique for this task was confirmed by determining the validation characteristics. The methodology at the appropriate level is characterized by specificity, linearity, correctness and convergence in the range of application for panthenol (range 20.33–38.26 mg/ml, ΔZ=0.93≤max ΔZ=3.20, a=0.63≤max a=5.12, r=0.9978≥min r=0.9924), phenylephrine hydrochloride (range 1.70–3.21 mg/ml, ΔZ=0.51≤max ΔZ=3.20, a=0.15≤max a=5.12, r=0.9984≥min r=0.9924), nitrofural (range 0.137–0.257 mg/ml, ΔZ=0.91≤max ΔZ=3.20, a=0.032≤max a=5.12, r=0.9987≥min r=0.9924) povidone (range 20,44–38,50 mg/ml, ΔZ=0.23≤max ΔZ=3.20, a=2.33 ≤ max a=5.12, r=0.9942≥min=0.9924), lidocaine hydrochloride (range 6.80– 12.81 mg/ml, ΔZ=0.34≤max ΔZ=3.20, a=0.66 ≤ max a=5.12, r=0.9988≥min r=0.9924), diphenhydramine hydrochloride (range 1.36–2.56 mg/ml, ΔZ=0.20≤max ΔZ=3.20, a=0.15≤max a=5.12, r=0.9980≥min r=0.9924). There are no significant changes when stored at 25 °C for 6 months. Conclusions. An analytical method of quantitative determination of the component composition in an extemporaneous nasal spray by a complex method of high-performance liquid chromatography has been developed. The determined validation parameters confirm the correctness of the methodology. The chemical stability of the dosage form is observed for 6 months
URI (Унифицированный идентификатор ресурса): http://dspace.nuph.edu.ua/handle/123456789/34241
Располагается в коллекциях:Наукові публікації кафедри фармацевтичної хімії



Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.