Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.nuph.edu.ua/handle/123456789/19865
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorDrapak, I. V.-
dc.contributor.authorДрапак, І. В.-
dc.contributor.authorZimenkovsky, B. S.-
dc.contributor.authorЗіменковський, Б. С.-
dc.contributor.authorPerekhoda, L. O.-
dc.contributor.authorПерехода, Л. О.-
dc.contributor.authorKovalenko, S. M.-
dc.contributor.authorКоваленко, С. М.-
dc.contributor.authorLogoyda, L.-
dc.date.accessioned2019-10-01T09:28:53Z-
dc.date.available2019-10-01T09:28:53Z-
dc.date.issued2019-
dc.identifier.citationDevelopment and validation of LC-MS/MS method for estimation of urocarb in human plasma / I. V. Drapak, B. S. Zimenkovsky, L. O. Perekhoda, S. M. Kovalenko, L. Logoyda // Int J App Pharm. - 2019. - Vol. 11. - Р. 125-130.uk_UA
dc.identifier.urihttp://dspace.nuph.edu.ua/handle/123456789/19865-
dc.descriptionA highly sensitive, specific, reproducible, rapid and high-throughput LC-MS/MS assay was developed and validated to quantify urocarb in human plasma as per the regulatory guidelines. Due to the sensitivity of the developed method, it can be applied to the monitoring of plasma levels in the analysis of drug in preclinical and clinical pharmacokinetic studies. All the parameters and results were found within the acceptance limit as given in the validation protocol.uk_UA
dc.description.abstractThe total chromatographic run time was 2.0 min and the elution of urocarb and IS (etomidate) occurred at ~1.53 and 1.67 min, respectively. A linear response function was established at 1-100 ng/ml for urocarb and etomidate in human plasma. The % mean recovery for urocarb in LQC, MQC and HQC was 104.1 %, 100.0 % and 97.4 %. The lowest concentration with the RSD<20% was taken as LLOQ and was found to be 1.03 ng/ml for urocarb. The within-run coefficients of variation ranged between 0.271 % and 0.478 % for urocarb. The within-run percentages of nominal concentrations ranged between 99.12 % and 100.21 % for urocarb. The between-run coefficients of variation ranged between 0.388 % and 0.601 % for urocarb. The between-run percentages of nominal concentrations ranged between 98.78 % and 101.11 % for urocarb.uk_UA
dc.language.isoenuk_UA
dc.publisherInternational Journal of Applied Pharmaceuticsuk_UA
dc.subjectLC-MS/MSuk_UA
dc.subjecturocarbuk_UA
dc.subjecthuman plasmauk_UA
dc.subjectvalidationuk_UA
dc.subjectpharmacokinetic studiesuk_UA
dc.titleDevelopment and validation of LC-MS/MS method for estimation of urocarb in human plasmauk_UA
dc.typeArticleuk_UA
Располагается в коллекциях:Наукові публікації кафедри медичної хiмiї

Файлы этого ресурса:
Файл Описание РазмерФормат 
33873-Article Text-164523-1-10-20190910.pdf319,43 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.